Fabric OS Reference Manual
Telnet Commands 29
cmemRetentionTest
Data retention test of the central memory SRAMs.
Synopsis
cmemRetentionTest [passCount]
Availability admin
Description Use this command to verify for data retention in the central memory
SRAMs in the ASIC.
Note
This command cannot be executed on an operational switch. You
must first disable the switch using the switchDisable command.
Operands This command has the following operand:
passCount
Specify the number of times to execute this test. The
default value is 1. This operand is optional.
Example To run the data retention test on the central memory SRAMS:
Errors There are three possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
See Also
camTest
centralMemoryTest
cmiTest
crossPortTest
portLoopbackTest
ramTest
spinSilk
sramRetentionTest
switch:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.