Fabric OS Reference Manual
52 Fabric OS Reference Manual
or cables, bad GBICs or cables, or improper connection of SWL to LWL,
etc.), the following message is sent to the telnet shell:
One or more ports are not active, please double check
fibres on all ports.
The following message displays on the front panel:
One or more ports not cabled.
singlePortAlso Mode
Specify
singlePortAlso
mode by executing
crossPortTest
with a
value of 1 for the second argument:
switch:admin> crossPortTest 0, 1
In this mode, a port can
be cable loopbacked to itself (port M is connected
to port M) in addition to being cross connected (port M is connected to
port N). This mode can be used to isolate improperly functioning ports.
GBIC Mode
Activate GBIC mode by executing the following command prior to
executing
crossPortTest
:
switch:admin> setGbicMode 1
When activated, only ports with GBICs present are tested by
crossPortTest
. For example, if only port 0 and port 3 contain GBICs,
crossPortTest
limits testing to port 0 and port 3.
The state of GBIC mode is saved in flash memory and remains active (even
after reboots or power cycles) until it is disabled:
switch:admin> setGbicMode 0