Fabric OS Reference Manual

70 Fabric OS Reference Manual
Diagnostic Error Codes
The following table lists the error numbers, the POST test that generates the
error number, and the type of error.
Error Level 0 = panic (the switch reboots)
1 = critical
2 = error
3 = warning
4 = information
5 = debug
Error Message Additional information about the error.
Diag Err# The number of the error. This is a hexadecimal
4-digit code representing the error type.
Table 3. Diagnostic Error Codes
Error Number Test Error Type
0001 n/a DIAG-CLEAR_ERR
0002 n/a DIAG-BURNIN_START
0003 n/a DIAG-BURNIN_STOP
0004 n/a DIAG-POST_SKIPPED
0110 ramTest DIAG-MEMORY
0111 ramTest DIAG-MEMSZ
0112 ramTest DIAG-MEMNULL
040F portRegTest DIAG-BUS_TIMEOUT
0415 portRegTest DIAG-REGERR
0416 portRegTest DIAG-REGERR_UNRST
0B0F sramRetentionTest DIAG-BUS_TIMEOUT
0B15 sramRetentionTest DIAG-REGERR
0B16 sramRetentionTest DIAG-REGERR_UNRST
1020 centralMemoryTest DIAG-CMBISRTO