Example The following example shows how to display the temperature in all switch
components of an FC 6164:
sw5:admin>sgroupsupportshow “starbase”, “tempshow”
Group Type Group Name Member WWN
================ =================================
S32_6_1 starbase 10:00:00:60:69:10:57:91
10:00:00:60:69:10:56:79
10:00:00:60:69:10:58:89
10:00:00:60:69:10:57:dd
10:00:00:60:69:10:58:63
10:00:00:60:69:10:58:3f
Please wait for remote data!
value = 0
star7:root>
========================================
Information from Local Domain 7
========================================
27 30 31 33 32 Centigrade
80 86 87 91 89 Fahrenheit
========================================
Information from Domain 8
========================================
28 29 32 33 33 Centigrade
82 84 89 91 91 Fahrenheit
========================================
Information from Domain 9
========================================