HP Surestore FC Switch 6164 Installation and Reference Guide
Installing and Configuring the FC 6164 43
11.If you inserted the switch into the rack from the back, skip this step.
Reinstall the removed hardware:
a. Use the 16 #10-32 Phillips screws you removed in Step 9 to re-attach
the rack-mounting flanges to the switch (see Figure 14).
b. Use the two screws you removed in Step 8 to re-attach the latch plate
(see Figure 14). Make sure that there is a gap of approximately
3/16-inch between the edges of the latch plate and the edges of the
cutout in the rack-mounting flange.
c. Orient the hinge plates so that the sides that have the loops face each
other (see Figure 15). Use the eight #6-32 x ΒΌ-inch flat-head screws
you removed in Step 7 to re-attach the hinge plates to the left side of
the switch at the front end (see Figure 13).
Figure 15. Orienting the Hinge Plates Prior to Reinstallation
Loops