HP Surestore FC Swtich 6164 Quick Start Guide

62
Quick Start Guide
Diagnostic Tests
Available tests which are run from the local Telnet port are listed below,
along with the command to initiate each. See the Fabric OS Reference
Manual, for detailed information on commands.
Table 4. Diagnostic Tests for the 2250 Switches
Test Command Description
Error Log errDump Displays the error log without
page breaks.
Switch Offline switchDisable Sets the switch to offline state
necessary to run certain switch
diagnostics.
Memory Test ramTest Checks CPU RAM memory. Run
offline or online.
Port Register
Test
portRegTest Checks that the registers and static
memory in each ASIC can be
successfully accessed. Run
offline.
Central Memory
Test
centralMemoryTest Checks that the central memory in
each ASIC can be successfully
accessed. Run offline.
Control Message
Interface (CMI)
Conn Test
cmiTest Verifies that control messages can
be sent from ASIC to ASIC.
Run offline.
Content
Addressable
Memory (CAM)
Test
camTest Verifies CAM functionality.
Run offline.
Error Log errDump Displays error log without page
breaks.
Port Loopback
Test
portLoopbackTest Checks all switch main board
hardware. Frames transmitted are
looped back and received.
Run offline.