Hardware Operator's Guide
3-21
Operating in Manual Mode
Dismounting a Cartridge from a DLT Drive
To dismount a cartridge from a drive:
1. Obtain the drive number using the LSM management software and place the
drive offline.
2. Open the LSM right front door by using a latch key to unlock the top and
bottom latches. Refer to Figure 3-3.
3. Open the LSM left front door. For the standard door, pull gently from the
top right corner. For the expansion door, pull from the recessed area on the
right side.
4. Locate the desired drive.
5. Make sure that the job is done.
6. Make sure that the Operate Handle indicator is on. If it is not, press the
Unload button on the drive to unload the drive. The indicator will turn on.
7. Push the shuttle all the way back, pause for about two seconds, then release
the shuttle.
Figure 3-13. Mounting a Cartridge into the 9840 Drive
H C60489