LSM Specifications
Table A-9. LSM Second Power Distribuition Unit Requirements
Power configuration US/Canada 100 to 120 VAC
UL/CSA power cable
Europe 200 to 240 VAC
HAR power cable
Input voltage rangeNominal
voltage
100 to 120/200 to 240 VAC
120 to 230 VAC
Input current US/Canada:
Single phase 120 VAC
47 to 63 Hz
6 A Service
3 wire
International:
Single phase 200 to 240 VAC
47 to 63 Hz
3 A Service
3 wire
Table A-10. LSM Environmental Limits
Temperature
Operating
Storage
Shipping
15º to 32ºC (59º to 90ºF)
10º to 40ºC (50º to 104ºF)
-40º to 60ºC (-40º to 140ºF)
Relative Humidity
Operating
Storage
Shipping
20% to 80% (noncondensing)
10% to 95% (noncondensing)
10% to 95% (noncondensing)
Wet Bulb Maximum
Operating
Storage
Shipping
29.2ºC (84.5ºF)
35ºC (95ºF)
35ºC (95ºF)
Altitude
Operating
Storage
Shipping
0 to 3,048 m (0 to 10,000 ft)
0 to 3,048 m (0 to 10,000 ft)
0 to 15,240 m (0 to 50,000 ft)