The following table describes the available configurations.
Table 4-5 Configuration Options
Config Name Description Default
RECOVERY
ON/OFF
ON Library attempts to recover from errors.
OFF Library immediately stops moving if an error
condition occurs.
Default is RECOVERY ON, and recovery should remain ON
under normal conditions.
ON
RESTORE
DEFAULTS
Sets all library configurations back to their default settings.
CLEAR
ODOMETERS
Used by service personnel only.
Sets all library odometers back to zero.
STARWARS
ON/OFF
Used by service personnel only. Set to ON during normal
operation.
ON Library runs with the vertical sensors enabled.
OFF Library runs with the vertical sensors disabled.
ON
NEW PASSWORD Changes the numerical password required to access ADMIN*
options (configurations, tests, and information logs). To
change the password, see “Setting a New Administration Menu
Password” on page 4-8.
SECURE ON/OFF Toggles between ON and OFF. If the configuration is set to ON,
tape magazines cannot be loaded or removed. If the
configuration is set to OFF, the library operates in its default
state, which allows cartridges to be loaded and removed.
OFF
POWER SECURE
ON/OFF
ON SECURE ON/OFF configuration setting is retained
after a power outage.
OFF Library returns to its default setting of POWER
SECURE OFF when power is returned after being shut
off.
OFF