HP DLT Tape Library 15-Slot - (English) User's Guide

4-44
Library Operation
Troubleshooting
Table 4-11 Troubleshooting
Problem Solution
Library will not power on. Make sure the power cord connections are tight.
Make sure the power switch is switched on. (The power
switch is located on the library control panel, see Figure 4-1
on page 4-3.)
Make sure the power outlet is operating.
Replace the power cord with a known good one.
If the library still won’t power on, call a service
representative.
Power on self test failed.
DEVICE FAILED displays.
Verify that all tapes in the bulk load magazines are fully
inserted in the magazines, and that the magazines are
securely locked into position inside the tape library.
Press the power switch off and then on again. (See the
caution note at the end of this table.)
If the power on test continues to fail, press
ENTER
, write
down the displayed error code, and call a service
representative for assistance.
DEVICE FAILED displays.
Hardware Error #61
(External SCSI cables) is
reported.
Make sure that only differential SCSI device type is used on
the SCSI bus.
Verify that the library SCSI selector switch is set correctly
(differential).
Verify that the bus is properly terminated.
The library’s power failed
while a cartridge was in the
drive and did not return to
the drive status indicators
("ready" state) after the
power came back on.
Press the power switch off and then on again. (See the
caution note at the end of this table.)
If the power on test is unsuccessful, switch off the power.
Call a service representative for assistance.