Cartridge Array Installation Instructions

62106 3
6. Remove the left theta stop from its current position (A) and install it at the new position
(B) shown in Figure 2.
CAUTION: This stop MUST be installed. If it is not it could cause damage to the
hand and/or the rear cover.
7. Close the left door of the tape library and lock the latches. Close the right front door.
Power on the tape library. Verify that the tape library initializes and audits.
8. Return the tape library back to the customer.
Array and Retainer Clips(a5604_02)
1. Retainer Clip
Figure 2. Theta Stop
Theta Stop (a5604_01)
2. Z-Column
3. Remove theta stop from position A
4. Install removed theta stop at position B
Figure 1. Array and Retainer Clips (Continued)