Table A–5. Power Specifications
Item Measurement
Input Voltage 90–264 VAC, single phase
Frequency 47–63 Hz
Maximum power consumption (library) 1.0 A at 120 V or 0.5 A at 240 V
Table A–6. Environmental Specifications
Item Measurement
Operating Storage Transit
Temperature 16 to 32_C
(60 to 90_F)
4 to 32_C
(40 to 90_F)
–40 to 60_C
(–40 to 140_F)
Relative Humidity 10 to 90% 10 to 95% 10 to 95%
Wet bulb (max,
noncondensing)
35_C
(95_F)
33_C
(92_F)
35_C
(95_F)
Altitude –76 to 3,048 m (–250 to 10,000 ft)
Agency Certifications
Table A–7. Agency Certifications
Category Certification
CSA standard CAN/CSA–C22.2 no. 950–M93
Safety
UL standard 1950, Third Edition
y
EN60950
FCC #47, Part 15, Subpart B, Class A
EMC Framework AS/NZS 3598: 1995 (Australia, N.Z.)
VCCI Class A
Emissions
European Union CE emissions standards
Canadian EMC Law; ICES–003
Korean EMC Law
BCIQ EMC Law CNS 13438 (Taiwan)
Immunity
European Union CE immunity standards
I