HP SureStore E Tape Library Model 6/140 User's Guide

Getting Started
Installing the Library (for Authorized Service Personnel only)
Chapter 11-6
Choosing a Location
Choose a location that meets the criteria listed in Table 1-2. For
additional specifications, refer to Appendix A or the product information
labels located on the back of the library.
NOTE Locate the AC outlet near the library. The AC power cord is this products
main AC disconnect device and must be easily accessible at all times.
Table 1-2 Location Criteria
Room
temperature
10-35º C (50-95º F)
Power source AC power voltage: 100-127 V or 200-240 V
Autoselecting
Line frequency: 50-60 Hz
A dedicated circuit is required
NOTE: The power cord supplied with the library is
4.5 meters (14.76 feet) in length.
Library power
consumption
Model 4/100 Typical: 425W, Max: 450W
Model 6/100 Typical: 565W, Max: 600W
Model 6/120 Typical: 590W, Max: 625W
Model 6/140 Typical: 615W, Max: 650W
Model 8/140 Typical: 755W, Max: 800W
Model 10/140 Typical: 895W, Max 950W
Model 12/140 Typical: 1035W, Max 1100W
LAN
connection
Locate the library near a LAN connection for
connecting the remote management card.