SAN Solution Installation Guide

Installation
Fibre Channel Bridges
Chapter 22-30
Connecting the HP SureStore E Bridge FC 4/1 HV to the FC SAN:
1. Locate the FC port on the back of the bridge.
2. Remove the GBIC protector and push the metal latch down to lock it
into place (see Figure 2-9).
Figure 2-9 GBIC Protector
3. With the bridge powered-off, connect it to your FC environment using
the appropriate cabling. The FC optical connectors on the bridge’s
GBIC are keyed. Be sure to insert the cable connectors in the proper
orientation.
Connecting the HP SureStore E Bridge FC 4/1 HV to a SCSI Bus:
1. Power-off your SCSI devices.
2. Connect a SCSI cable to one of the SCSI connectors on the back of the
bridge.
3. Connect this cable to one of the SCSI connectors on your library.
4. Make sure the bus is terminated correctly. By default, the bridge is
automatically terminated, but be sure that the device at the other end
of the bus (your library) is also terminated.
5. Power-on your SCSI library.
6. After all the SCSI devices have completed the self-tests, power-on the
bridge.