HP StorageWorks 200 Storage Virtualization System owner's guide (AE071-96004, October 2006)

Humidity
Protect the system from excessive humidity. You should not obser ve condensation in or
around the pro
duct under any conditions. There is no procedure for recovery from
moisture condensation
Humidity rang
etype
Noncondensin
grelativehumidity(RH)
Operating humidity range at 22
degrees C (71 degrees F)
20% to 80%
Nonoperating humidity range
8% to 90%
Shipping and storage humidity range
(product p
acked in factory packing)
5% to 95 %
Operating maximum wet bulb
temperature
26 degrees C (79 F)
Nonoperating maximum wet bulb
temperature
27 degrees C (81 F)
Shipping and storage maximum wet
bulb temperature
29 degrees C (84 F)
Mechanical vibration
Continuous vibration can cause a slow degradation of mechanical parts. Mechanical
conne
ctions such as printed circuit assembly (PCA) conductors, cable connectors, and
processor backplane wiring can all be affected by vibration. Vibration specications
apply to all three axes.
Condition
Spec
ication
Operating 0.25 mm, 5–10 Hz
0.05 G, 10–300 Hz
Nonoperating
2.5 mm, 510 Hz
0.5 G, 10–70 Hz
0.05 mm, 70–99 H z
1.0 G, 99–300 Hz
32