HP Systems Insight Manager 6.3 User Guide

A Important Notes
System and object names must be unique
System and object names must be unique in Systems Insight Manager.
For example, the name of a Virtual Connect Domain must not be identical to the name of a Virtual
Connect Switch, or they can be confused in Systems Insight Manager. The Virtual Connect Domain
is a virtual system with no physical network address. The Virtual Connect Switch is a physical
system that is network addressable.
Setting the Primary DNS Suffix for the CMS
IMPORTANT: If the Windows server you are installing Systems Insight Manager onto is a
multi-homed system serving up multiple IP addresses across multiple domains, then it is important
that the server has the primary DNS suffix defined for the system. The primary DNS suffix must be
displayed in the System Properties as part of the Full computer name for the server.
In Windows:
Procedure 35 Setting the Primary DNS suffix of the CMS BEFORE installation
1. From the Windows Control Panel, click System. The System Properties window appears.
2. Select the Computer Name tab. The Computer Name window appears.
3. Click More. The DNS Suffix and NetBIOS Computer Name window appears.
4. Enter the primary DNS suffix name in the Primary DNS suffix of this computer field.
5. Continue clicking OK until you return to the Control Panel.
To fix the issue AFTER Systems Insight Manager installation, complete the following:
Procedure 36 Deleting duplicate CMS AFTER installation
1. From the command line, run ipconfig/flushdns.
2. In the Systems Insight Manager UI, on the system view page, select the duplicate CMS system
you want to remove.
3. Click Delete. If the system cannot be deleted, select the other CMS system and delete it.
4. Select the remaining CMS system, and then select OptionsIdentify Systems.
5. Select target systems, and then click Run Now.
Distributed Systems Administration Utilities menu options not available
The Distributed Systems Administration Utilities (DSAU) menu items do not work on a Systems Insight
Manager 6.0 HP-UX CMS. A new version of DSAU will be released to the web in the first half of
2010.
Virtual machine guest memory reservation size
If Systems Insight Manager is installed on a virtual machine guest, but does not start and an empty
mxdomainmgr.0.log file is observed in the installation/logs directory, then use the virtual
machine configuration tools to set the guest's memory reservation size to be a minimum of 4GB.
146 Important Notes