HP Systems Insight Manager 5.3 Technical Reference Guide

1. From the HP-UX managed system, run /ect/opt/resmon/lbin/send_test_event monitor
name . For example, /etc/opt/resmon/lbin/send_test_event disk_em.
Possible monitor names:
dm_memory
lpmc_em
disk_em
dm_chassis
dm_core_hw
ia64_corehw
fpl_em
2. Confirm that the test indication is shown in the HP SIM event table view after you trigger it.
3. Additionally, on the HP-UX managed system, you can run /opt/sfm/bin/evweb eventviewer
-L to verify that indications are generated and received on the local system. This command lists all of
the WBEM events that have been generated on the system.
Related procedures
Adding a WMI Mapper Proxy
Deploying OpenSSH to multiple systems using RDP
Installing OpenSSH
Creating an OpenSSH task through the CLI
Configuring DMI access
Configuring SNMP access
Related topics
Global protocols
WMI Mapper Proxy
Configuring or repairing agents
Configuring automatic discovery general settings
1. Select OptionsDiscovery. The Discovery page appears.
2. In the For all automatic discoveries section, select Configure general settings. The General
Settings for All Discoveries section appears.
3. Select from the following options:
Automatically discover a system when an event is received from it. This option enables
systems to be discovered when a trap or some other supported event is received by HP SIM. It
uses the discovery filters and IP address exclusion ranges for additional filtering of these events.
This option is not selected by default.
Automatically discover a server when its Integrated Lights Out management processor
is identified. This option adds servers indirectly discovered through the server's management
processor, which are discovered when the server's iLO is discovered. The discovered servers are
identified as Disabled on the system table view page. The only information displayed is the system
serial number and the association to iLO and the enclosure. If the iLO is in a c-Class enclosure,
the option, Discover systems in an enclosure when Onboard Administrator is discovered
must be enabled.
Discover systems in an enclosure when Onboard Administrator is discovered. This option
adds systems identified by the Onboard Administrator even if the systems are not in the configured
discovery range. This option is selected by default.
Configuring automatic discovery general settings 109