HP Systems Insight Manager 5.3 Technical Reference Guide

When running a Data Collection task, I receive the following error on the Task Results page in the Target
Details section for a storage system: An unexpected error was encountered in the middle
of communication with the CIMOM.
Possible causes:
The CIMOM was stopped.
The system running the CIMOM is down.
There are problems with the network between the CMS and the system running the CIMOM.
An unexpected error occurred within the CIMOM.
Solution
Verify that the CIMOM is running and responding to requests from the CMS.
When running a Data Collection task, I receive the following error on the Task Results page in the Target
Details section for a storage system: The CIMOM for this device rejected the credentials
supplied.
Possible causes
The username and password have been changed in the CIMOM, and the new values have not been
entered into HP SIM, or were entered incorrectly.
The CIMOM is configured to require a client certificate that matches one in its keystore, and the certificate
is no longer there.
Solution
Enter the correct username and password in HP SIM. See “Configuring HP SIM with storage systems
or “SMI-S providersfor more information.
When running a Data Collection task, I receive the following error on the Task Results page in the Target
Details section for a storage system: The CIMOM is no longer managing this device.
Possible causes:
The device was removed from the list of devices managed by the CIMOM from which it was originally
discovered.
The CIMOM has lost connectivity to the device, and is no longer able to report on it.
Solutions:
Ensure that the CIMOM has this device in its list of devices to manage, and that it is able to connect
to the device and gather data for it.
Choose a different CIMOM to manage the device, and then:
Enter the IP address and credentials for that CIMOM in HP SIM. See “Configuring HP SIM with
storage systemsfor instructions.
1.
2. Delete the device from HP SIM and run a discovery task to discover the device through the new
CIMOM.
When running a Data Collection task, I receive the following error on the Task Results page in the Target
Details section for a storage system: An unexpected error was returned while writing to
the database.
Possible causes
The database and/or LUN on which it resides is full.
Some unanticipated data from the CIMOM could not be handled by the persistence layer or the
database.
An unknown problem occurred in the persistence layer of the database.
Solution:
Make sure that the database has adequate space to insert new data.
Switch
After discovering and identifying an HP ProCurve Switch, the switch management page does not appear
when I click the HP ProCurve switch link under the System Page, Link tab.
Switch 649