HP Systems Insight Manager 5.3 Technical Reference Guide

DescriptionData TypeColumn Name
Node partly identifies dc_EnclosureBIGINTNodeID
Snapshot partly identifies dc_EnclosureBIGINTSnapshotID
Tag partly identifies dc_Enclosure and is an arbitrary string
that uniquely identifies the enclosure and serves as the
Element key
NVARCHAR(256)Tag
The unique address of the enclosure within the rackINTdc_Address
The maximum number of server blades the enclosure can
contain
INTdc_EnclosureMaxNumBladesX
The maximum number of server blades the enclosure can
contain
INTdc_EnclosureMaxNumBladesY
Specifies if the fuse described is present in the system: Other
(1), Absent (2) and Present (3)
NVARCHAR(32)dc_FusePresent
The condition of the fuse ( Other (1), Fuse status detection
is not supported, OK (2), Fuse is operating properly, Failed
(4), Fuse has been tripped or is not operating properly)
NVARCHAR(32)dc_FuseCondition
DC_ProliantHost table
DescriptionData TypeColumn Name
LUID uniquely defining this table rowBIGINTProliantHost_LUID
Identifies the system ID for this rowBIGINTNodeID
Identifies the snapshot ID for this rowBIGINTSnapshotID
Equates to CIM_ComputerSystemNVARCHAR(256)dc_SystemCreationClassName
The value of CIM_ComputerSystem.Name where NodeID
is equal.
NVARCHAR(256)dc_SystemName
This object represents the overall status of the server host
system represented by this MIB
NVARCHAR(16)OverallCondition
An array of MIB status structures (Each structure is made
up of 4 octets. The first octet is the MIB presence. The
second octet is MIB condition. The third octet is MIB major
revision. The fourth octet is MIB minor revision. These blocks
of 4 octets each are index by the mib identifier just after
the HP enterprise (for example, in 1.3.6.1.232.11 mib,
the index is 11). The 4 octets in the first block (block 0) are
reserved for systems management and serve as an
aggregate of their MIBs.)
NVARCHAR(512)MIBStatusArray
The globally unique identifier of this server (If the operating
system cannot determine a unique ID, it defaults the variable
to contain all 0's. The management station can then perform
a SET to this variable to provide the unique ID.)
NVARCHAR(64)GUID
This item indicates the port used by the HP Insight
Management Agent
INTWebManagementPort
The Automatic Server Recovery (ASR) feature status (If this
object is currently Other (1) or Not Available (2), all set
operations fail. Any attempt to set this object to Other (1)
or Not Available (2) by a management station fails. Setting
this object to Disabled (3) or Enabled (4) disables or
enables the ASR feature.)
NVARCHAR(16)ASRStatus
The HP System ID; this value indicates the HP system ID of
the system board in this system (This ID replaces the product
ID used in older machines (cpqSiProductId). A value of 7Eh
for the cpqSiProductId indicates that the cpqSiSystemId
should be used to identify the HP system. A value of zero
(0) indicates that the system ID function is not supported on
this machine. In this case, the cpqSiProductId should be
used to identify the system.)
INTSystemID
Database tables 695