PCoIP Zero Client and Host Administrator Guide (Issue 5)
Table 4-110: OSD Change Password Page Parameters
Parameter Description
Old Password This field must match the current administrative password before you
can update the password.
New Password The new administrative password for both the AWI and the local OSD
GUI.
Confirm New Password This field must match the New Password field for the change to take
place.
Reset If the client password becomes lost, you can click the Reset button to
request a response code from the zero client vendor. The challenge
code is sent to the vendor. The vendor qualifies the request and
returns a response code if authorized by Teradici. When the
response code is correctly entered, the client's password is reset to
an empty string. You must enter a new password.
Note: Contact the client vendor for more information when an
authorized password reset is required. This option is not available
through the AWI. It is only available through the OSD.
7.30 Configuring Reset Parameters (AWI/OSD)
7.30.1 AWI Client: Parameter Reset Settings
The Reset Parameters page lets you reset configuration and permissions to factory default
values stored in flash memory. You can access this page from the Configuration > Reset
Parameters menu.
Note: Resetting parameters to factory default values does not revert the firmware or clear
the custom OSD logo.
Figure 4-123: AWI Client Reset Page
TER1206003 Issue 5 331
PCoIP® Zero Client and Host Administrator Guide