HP Server Ultra 3 SCSI Host Bus Adapter Installation and Configuration Guide

Chapter 2 Configuration with SCSISelect
12
1
Setting is valid only if Multiple LUN Support is enabled
2
Settings are valid only if host adapter BIOS is enabled
Initiate Wide Negotiation Yes, No Yes (Enabled)
Enable Disconnection Yes, No Yes (Enabled)
Send Start Unit Command Yes, No Yes (Enabled)
Enable Write Back Cache
1
N/C (No Change)
Yes, No
N/C (No
Change)
BIOS Multiple LUN Support
2
Yes, No No (Disabled)
Include in BIOS Scan
2
Yes, No Yes (Enabled)
Advanced Configuration Options:
Reset SCSI Bus at IC
Initialization
Enabled, Disabled Enabled
Display <Ctrl> <A> Messages
during BIOS Initialization
Enabled, Disabled Enabled
Extended BIOS Translation for
DOS Drives > 1 GByte
Enabled, Disabled Enabled
Verbose/Silent Mode Verbose, Silent Verbose
Host Adapter BIOS Enabled
Disabled: Not Scan
Disabled: Scan Bus
Enabled
Domain Validation
2
Enabled, Disabled Enabled
Support Removable Disks Under
BIOS as Fixed Disks
2
Disabled, Boot Only,
All Disks
Disabled
BIOS Support for Bootable
CD-ROM
2
Enabled, Disabled Enabled
BIOS Support for Int 13
Extensions
2
Enabled, Disabled Enabled
Table 2-1. SCSI Select Options
SCSISelect Options Available Settings
Default
Setting