ACC Installation and Configuration Guide
Chapter 3 61
Protocol Configuration
Creating a Downloadable Firmware File
All other lines must be duplicated exactly as shown in the loopback.zlnk
file.
The example that follows is for an HP-PB (NIO) backplane, 8-port ACC
product. It shows the /opt/acc/z7200a/loopback.zlnk file with
modifications to include the X.25 protocol module. The edits that were
made to the original loopback.zlnk file are shown in bold.
Also note that files shown in the “Required ZLNK Directives” section of
this example vary with the ACC hardware platform. Refer to the sample
loopback.zlnk file provided with your software product.
Sample .zlnk File
* Create a map file to describe what is contained in the
* absolute firmware file
ma z7200a/loopx25.zmap
* Modify the ”nam” to reflect what is contained in the
* resultant firmware file.
nam VMUX-1.1 Loopback and X.25 Download file for HP-UX Zcom System
sn sys/vmux302a.zsnp
org,vmux1org, vmux1lim
re sys/wmux1.zrel
org,vmux3org, vmux3lim
re sys/wmux3.zrel
org,progorg, proglim
re sys/wmux4.zrel
re protocol/level1.zrel
******************* Protocol Modules **********************
re protocol/zx25.zrel
**************** End of Protocol Modules ******************
re protocol/monitor.zrel
re protocol/testprot.zrel
org, eptable
re sys/pmenttab.zrel
org, preptbl
re sys/umuxent.zrel
* Absolute file that is created:
ab z7200a/loopx25.zabs
end
For this example, assume that zlink is to be run from the /opt/acc/
directory (but this is not a requirement) and t he new .zlnk file name is
/opt/acc/z7200a/loopx25.zlnk.