ZMNTR - ZCOM Runtime Monitor
Commands
Example - E1/T1 ACC card:
Interface card information for Typical ACC configuration
TTGEN source /opt/acc/cfg/x25_4ch_sample.answ
object /opt/acc/cfg/x25_4ch_sample.tmem
Mux:00 Bus:00/56 Slot:36 Trms:0022 Card Stat:Up and active
Hardware Revision: Rev.A
Firmware download file: /opt/acc/z7300a/x25.zabs
ROM-ID: Z7300A [01.F] Updated: Sun Jun 23 15:06:00 1996
Connection: Coax BNC panel MPU activity: 39%
Pt# PMode Ecode Frame Clock
0 E1R45 HDB3 CRCMF Int
1 E1R45 HDB3 CRCMF Ext
2 E1R45 HDB3 CRCMF Int
3 E1R45 HDB3 CRCMF Ext
Use the 'S' option to display subchannel and timeslot configuration.
The following Mux card information displayed in the listing:
Mux The Mux number assigned to this interface in the
TTGEN configuration file.
Bus The bus converter address for this interface. Note that
usage of this term varies with type of HP 9000 system.
Slot The slot within the backplane bus where this interface
is installed.
Trms The number o f terminals configured on this ACC card.