ACC Utilities Reference Guide
112 Chapter4
ZMNTR - ZCOM Runtime Monitor
Commands
Card Stat This is the current card sta te. For normal operation,
this should be Up and Active. Other possible states are:
• Driver/Interface not initialized
•Beingreset
•Timedout
• Power failed
• Card down (serious error)
• Firmware fail ure
• Operator reset
• DMA interrupt error
• Card dead, no activity
• Card absent
• Fatal hardware error
If the card is not physically installed in the correct I/O
slot or bus, the state will be card absent.Ifthisstateis
displayed, use the utility ioscan t o check that the card
is installed correctly. The card H/W IODC value is
0x4d80.
Firmware Thefirmwaredownloadfileisthenameofthefilethat
ZMON downloads to the ACC card when ZCOM is
initialized, or when ZMON restarts the ACC card after
a power failure, or other card failure (for example,
firmware failure or operator reset). For non-E1/T1 ACC
cards the linktime fieldisthedateandtimethis
download file was built by ZLINK.
ROM-ID The ID value read by ZMON from the EPROM on the
ACC interface. The updated fieldshowsthedateand
time this EPROM was last revised.
Connection This field identifies the type of panel or cable connected
to the ACC card. If no panel or ca ble is connected, this
field will read No connector attached or (for an E 1/T1
card) No panel attached.
MPU Activity The MPU activity field shows the current processor
utilization on the ACC interface. This field is updated
every 10 seconds and is the average utilization during
the last 10 seconds.