ACC Utilities Reference Guide
118 Chapter4
ZMNTR - ZCOM Runtime Monitor
Commands
TM - Set Auto Repeat Time Interval
Format: TM,nn
Thecommandsetsthetimeoutvalueto“nn” seconds between 0 and 200.
If set to 0, the timeout is cleared and the command does not repeat.
Otherwise the last command entered will be repeated every “nn”
seconds.
Enter TM and the repeat time (anything between 1 and 5 inclusive is
treated as 5 seconds). Then enter the command to be repeated.
Use TM,0 to cancel the auto-repeat timeout and return to normal
operation.
Example
TM,30
TT,1,100
This sequence of commands will cause the TT,1,100 command to be
repeated every 30 seconds.
TO - Top of Form on List Device
Format: TO
This command causes a form feed t o be sent to the printer. It has no
effect if the list device is a terminal.