ACC X.25 Protocol User's Guide
42 Chapter3
ZX25D X.25 Protocol Driver
Configuration
Select Word for an X.25 Link Configuration
Hunt Group Configuration
Hunt groups are not supported by the zx25d driver.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
T2 Res T2 Timer (1-63) K (1-7) N2 (1-31)
T2 Res 0-3 T2 timer resolution value
0
1
2
3
10 ms
100 ms
1Sec
10 Secs
T2 Timer 1-63 Set Timer 2 to value given (1 to 63), and Set Timer 1
to value given * 2 (2 to 126). Note that 0 is an error
and is not allowed.
K 1-7 L2 Window size values 1 to 7 allowed. Note that 0 is
an error and is not allowed. When using modulus 128
operation at level 2 (with L2E set to 1), this field
provides the least significant three bits of the window
size, and all values are allowable. See “Extended K”
field description
N2 1-31 Level 2 retry counter, values 1-31 allowed. Note that 0
is an error and is not allowed.