HyperFabric Administrator's Guide (HP-UX 11i v1)

Planning the Fabric
Hyper Messaging Protocol (HMP)
Chapter 236
Maximum Cable Lengths
HF1 (copper): The maximum distance between two nodes or between
a node and a switch is 60 ft. (2 standard cable lengths are sold and
supported: 35 ft. and 60 ft.)
HMP supports up to 4 HF1 switches connected in series with a
maximum cable length of 60 ft. between the switches and 60 ft.
between switches and nodes.
HF2 (fiber): The maximum distance is 200m (4 standard cable
lengths are sold and supported: 2m, 16m, 50m and 200m).
HMP supports up to 4 HF2 switches connected in series with a
maximum cable length of 200m between the switches and 200m
between switches and nodes.
HMP supports up to 4 hybrid HF1/HF2 switches connected in series
with a maximum cable length of 60 ft. between copper ports and
200m between fiber ports.
HMP is supported on A400, A500, rp2400, rp2450, rp54xx (N-class),
rp74xx (L-class), rp8400, and Superdome servers running 64-bit
HP-UX.
HMP is supported on workstations running 64-bit HP-UX when
patch number PHNE_25485 or above is installed.
HMP is supported on HyperFabric starting HyperFabric versions
B.11.00.11 and B.11.11.01.
HMP is not supported on the A180 or A180C server.
HMP is not supported on 32-bit versions of HP-UX.
Throughput and Latency
Table 2-4 HF1 Throughput and Latency with HMP Applications
Server Class Maximum Throughput Latency
rp 7400 1.28 + 1.28 Gbps full duplex per
link
< 26 microsec