HyperFabric Configuration Guidelines

HyperFabric Configuration Guidelines
Hyper Messaging Protocol (HMP)
43
Configuring HMP for Local Failover Support
This section describes how to use SAM to configure HMP for Local
Failover Support.
IMPORTANT Currently, you must use only SAM to configure HMP for Local Failover
Support.
To use SAM to configure HMP for Local Failover Support, follow these
steps:
Step 1. Start SAM.
Step 2. Select the Networking and Communications area.
Step 3. Select HyperFabric.
All HyperFabric adapters installed in the system are listed; installed
adapters that are not yet configured show Not Configured in the
Status field. Before proceeding to the next step, configure all the
available adapters.
Step 4. Pull down the "Actions" menu and select "Local Failover Configuration
for HMP". SAM now verifies the following:
If not all the adapters are configured
If the number of adapters configured are odd
If Interoperability Enabled is set to YES
If any of the above conditions is true, then SAM displays an
appropriate error message. Otherwise, the Configure Local Failover
for HMP window pops up.
Step 5. In this window, specify the configured adapters for each card pair and
press OK.
On pressing OK, SAM verifies the following:
If all card pairs are not configured
If you have chosen the same adapter for different card pairs