ACC Error Guide

ZMON Error Messages
ZMON Error Messages
Chapter 6126
Message 050 - Card number out of range, restart ignored
Explanation: Message printed as a result of the ZMON RESTART
request being issued with an invalid card (MUX
interface) number.
Action: Reissue the RESTART request with the correct card
number.
Message 051 - Card number out of range, shutdown ignored
Explanation: Message printed as a result of the ZMON SHUTDOWN
request being issued with a Mux number larger than
the number of muxes (actually N-1) configured in the
TTGEN memory image file.
Action: Reissue the SHUTDOWN request with the correct card
number.
Message 052 - Card <number> shutdown completed
Explanation: Message printed as a result of the ZMON SHUTDOWN
request being issued. Once this message appears the
card is shutdown and the amber LED is flashing on the
back of the card. The card may be restarted using the
ZMON RESTART command.
Action: None
Message 060 - ioctl(status) error: <zcom error>
Explanation: Message is displayed after a ZMON STATUS request is
issued and ZMON cannot successfully read the ZCOM
status.
Action: If problem persists report it to HP.
Message 061 - Status since <date/time> - Aborted (must reset)
Explanation: Message printed as a result of the ZMON STATUS
request being issued. This status means that the
ZCOM system has failed during a previous startup,
and is unusable.
Action: A cold start is needed to bring up an usable ZCOM
system.