ACC Error Guide
ZMON Error Messages
ZMON Error Messages
Chapter 6 131
Message 106 - Card <number> request ignored because IFT is not
initialized
Explanation: ZMON tries to process a startup or shutdown request
for an interface card, but the card information is not
defined (e.g. it is skipped in the TTGEN configuration
file). The card information is contained in the ZCOM
IFT (interface table), and can be read via the
/dev/zmon device file. This error indicates the IFT is
not set up. The startup or shutdown of the card is
abandoned if this error is encountered
Action: ZMON expects the cards of number 0,1,2,… up to the
largest card number are all defined in the TTGEN
configuration file. ZMON logs this message if any card
number in-between is not defined. This message can
just be ignored if it is intentional to skip an interface
card definition. Otherwise, the appropriate information
with the missing card number should be defined in the
Interface-Definition section of the TTGEN
configuration file.
Message 107 - Card <number> too many restarts, card DOWN
(unusable)
Explanation: The ZCOM system allows about 5 restarts of a Mux
card per minute. If the number of restarts exceeds this
value ZMON assumes there is a serious problem with
either the Mux card hardware or software and will
abandon its attempts to continue to restart the card.
Action: If the problem is as a result of a software error in the
Mux card the download module can be replaced with a
good version and the Mux card restarted using the
ZMON RESTART request. If the problem is hardware
related the Mux card must be replaced.
Message 108 - Card <number> startup aborted
Explanation: ZMON has abandoned the Mux startup. The reason
will be given in a previous message.
Action: Take action appropriate to the reason given in the