ACC Error Guide

ZMON Error Messages
ZMON Error Messages
Chapter 6 145
Message 249 - Card <number> firmware object file <file-name> not
executable
Explanation: Message issued when ZMON encounters a corrupt
record in the firmware download file for the Mux card.
The Mux will be unusable until the problem is rectified.
Action: Replace the corrupt firmware file with a clean file and
restart the Mux card with ZMON RESTART or restart
ZCOM with ZMON COLD.
Message 250 - Card <number> COFF header access error on
<file-name>
Explanation: Message issued when ZMON encounters a corrupt
record in the firmware download file for the Mux card.
The Mux will be unusable until the problem is rectified.
Action: Replace the corrupt firmware file with a clean file and
restart the Mux card with ZMON RESTART or restart
ZCOM with ZMON COLD.
Message 251 - Card <number> Cannot seek raw data for section
<section-name>
Explanation: Message issued when ZMON encounters a corrupt
record in the firmware download file for the Mux card.
The Mux will be unusable until the problem is rectified.
Action: Replace the corrupt firmware file with a clean file and
restart the Mux card with ZMON RESTART or restart
ZCOM with ZMON COLD.
Message 252 - Card <number> Short raw data in section
<section-name>
Explanation: Message issued when ZMON encounters a corrupt
record in the firmware download file for the Mux card.
The Mux will be unusable until the problem is rectified.
Action: Replace the corrupt firmware file with a clean file and
restart the Mux card with ZMON RESTART or restart
ZCOM with ZMON COLD.