ACC Error Guide
TTGEN Error Messages
Errors
Chapter 8188
Error 165: “%s”(%d): SDLC mode cannot specify parity
(Severity 2)
Explanation Port SDLC mode cannot specify parity. The specified
port configuration combination is invalid.
Action: Use an appropriate configuration.
Error 166: “%s”(%d): SYNC mode must specify parity
(Severity 2)
Explanation Port SYNC mode must specify parity. The specified port
configuration combination is invalid.
Action: Use an appropriate configuration.
Error 167: “%s”(%d): SYNC/SDLC mode have no stop bits
(Severity 2)
Explanation Port SYNC/SDLC mode must have no stop bits. The
specified port configuration combination is invalid.
Action: Use an appropriate configuration.
Error 168: “%s”(%d): Bad ZLU “%s” (range %d..%d), line ignored
(Severity 2)
Explanation The specified ZLU number is out of range. The line is
ignored in order to continue compilation.
Action: Use an appropriate value or adjust “TERMINAL-ZLU”
(of CONFIGURATION section) to accommodate the
required terminal ZLU.
Error 169: “%s”(%d): Re-defining ZLU %d, line ignored
(Severity 2)
Explanation The specified ZLU is already defined. The line is
ignored in order to continue compilation.
Action: Check the previously defined ZLU, and use different
values.
Error 170: “%s”(%d): Bad interface number ”%s” (range %d..%d)
(Severity 2)
Explanation The ACC interface card number specified is out of
range.
Action: Use an appropriate value or define that ACC card
number in the Interface-Definition section.