ACC Error Guide

TTGEN Error Messages
Errors
Chapter 8200
Error 257: “%s”(%d): Bad bquota %s (range %d..%d)
(Severity 2)
Explanation Valid bquota range is 1-1M.
Action: Change to an appropriate value.
Error 258: “%s”(%d): Bad tsize %s (range %d..%d)
(Severity 2)
Explanation Valid tsize range is 1-32k.
Action: Change to an appropriate value.
Error 259: “%s”(%d): Bad frame mode "%s", line ignored
(Severity 2)
Explanation Valid frame modes are F4, F12, D3/4, ESF and F72.
Action: Change to an appropriate value.
Error 260: “%s”(%d): Bad link code “%s”, line ignored)
(Severity 2)
Explanation Valid link codes are HDB3, B8ZS and AMI.
Action: Change to an appropriate value.
Error 261: “%s”(%d): Bad subchannel “%s” (range %d..%d)
(Severity 2)
Explanation Valid subchannel numbers are 0-31.
Action: Change to an appropriate value.
Error 262: “%s”(%d): Card %d should not have subchannel definition
(Severity 2)
Explanation Subchannel definition is legal for E1/T1 interface card
only.
Action: Delete illegal subchannel definition
Error 263: “%s”(%d): Invalid subchannel transmission mode: %s
(Severity 2)
Explanation Valid subchannel transmission modes are TRANSA,
TRANSB, V.110 and HDLC.
Action: Change to an appropriate value.