ACC Error Guide

TTGEN Error Messages
Errors
Chapter 8202
Error 271: “%s”(%d): Bad E1/T1 Port-Limit “%s” (range %u..%u)
Explanation The E1T1-Port-Limit parameter is out of range.
Action: Change to an appropriate value.
Error 272: “%s”(%d): No E1/T1 cards defined, so Port-Limit (%u) must
remain within the range %u..%u
Explanation The Port-Limit parameter may exceed it’s normal limit.
Action: Change to an appropriate value.
Error 273: “%s”(%d): Port-Limit (%u) must remain within %u..%u if
E1T1-Port-Limit is used in this file
Explanation The Port-Limit parameter must remain within normal
limits if the Port-Limit parameter is specified.
Action: Change to an appropriate value.
Error 274: “%s”(%d): Port %d is not well-defined
Explanation Cannot proceed with subchannel definition if port
definition has errors.
Action: Correct the port definition.
Error 275: “%s”(%d): Undefined or not well-defined subchannel %d
Explanation The subchannel specified for the terminal, was not
properly defined.
Action: Correct the subchannel definition.
Error 276: “%s”(%d): ‘%s’ Logical-data definition required
Explanation The “X25UDT” area must be defined before the UDATA
keyword can be used.
Action: Add the “X25UDT” Logical-Data definition to the
Configuration section.