ACC Error Guide
TTGEN Error Messages
Errors
Chapter 8 205
Error 289: "%s"(%d): Unrecognized subchannel keyword id: %d
(Severity 2)
Explanation The Subchannel definition has an unrecognized
keyword. The keyword id number displayed is an
internally used value.
Action: Check for misspelling. Correct the spelling or remove
the unsupported word. If the problem persists, this
may indicate an internal software problem, please
inform HP support center.
Error 294: "%s"(%d): Port clock-source must be another port
(Severity 2)
Explanation The clock source CLKPTx specified must be of a port
other than the port currently being defined in this
definition. (e.g., Port 0 cannot be specified to use
CLKPT0).
Action: Change the clock source CLKPTx to a port other than
the current port being defined.
Error 295: "%s"(%d): Port mode "%s" invalid for this card type
(Severity 2)
Explanation The port of this type of ACC card does not support the
port mode specified.
Action: Check for consistence of Interface/Port definition. Use a
correct port mode, or make sure the port being defined
is referring to the desired interface card.