ACC Error Guide
TTGEN Error Messages
Warnings
Chapter 8 211
Warning 326: “%s”(%d): Terminal name truncated to %d characters
(Severity 1)
Explanation The specified terminal name is too long and is
truncated.
Action: Simplify and shorten the terminal name to avoid
truncation.
Warning 327: “%s”(%d): No data specified “%s”, parameter ignored.
Action: Correct this parameter.
Warning 328: “%s %d”: The 1980 ITU-T recommendation X.25 does not
support D-Bit negotiation.
Action: Select 1988 X.25 support or do not use the D-bit.
Warning 329: “%s %d”: Unused bits of link Option Word not 0.
Action: Check why unused bits have been set.
Warning 330: “%s %d”: Invalid %s value (range %d..%d), using default
value of %d.
Action: Change to an appropriate value if the default is not
acceptable.
Warning 331: “%s %d”: The %s value is not compatible with the 1980
ITU-T recommendation X.25, using default of %d.
Action: Change to an appropriate value if the default is not
acceptable.
Warning 332: “%s %d”: The %s value is not compatible with ITU-T X.25
recommendation year, using default of %d.
Action: Change to an appropriate value if the default is not
acceptable.
Warning 333: “%s %d”: Extended throughput class negotiation not
enabled. Invalid %s value, using default of %d.
Action: Change to an appropriate value if the default is not
acceptable.