ACC Error Guide

ZMASTERD Log Messages
ZMASTERD Log Messages
Chapter 9218
Action: None, if you don’t want to restart the ZCOM
subsystem. However, if you want to stop and restart
the ZCOM subsystem, do zmasterd stop first before
issuing zmasterd again to restart the ZCOM
subsystem.
zmast 110 - Invalid daemon name entered.
Explanation: This message is displayed when an invalid daemon
name is entered for the zmasterd act or deact
command. zmasterd currently supports the following
daemons: pcapture, watch, zmlog, zmon and znode.
Action: Correct the daemon name related to the last zmasterd
command and retry.
zmast 111 - Daemon <name> is already active, command disallowed.
Explanation: This message is displayed when the zmasterd tries to
launch a daemon, but the specified daemon is already
active.
Action: None, or if you want to restart the daemon, use the
zmasterd deact <daemon> command first before the
zmasterd act <daemon> command.
zmast 112 - Build argument list failed, probably out of memory.
Explanation: This message is displayed when zmasterd failed to
allocate more memory.
Action: Free up some memory and retry.
zmast 113 - Invalid zmasterd command.
Explanation: This message is displayed when an invalid zmasterd
command is entered.
Action: See zmasterd man page for usage.
zmast 114 - Failed to send message to zmasterd: <reason>
Explanation: This message is displayed when zmasterd failed to send
message to the running zmasterd daemon.
Action: This is a zmasterd internal error. Report this problem
to your HP support representative.