ACC Error Guide

WATCH Log Messages
WATCH Log Messages
Chapter 11230
WATCH Log Messages
The following messages may be logged by the watch program via the
zmlog logging mechanism:
watch 2 - Cannot open /opt/acc/cfg/zcomdevice file
Explanation: The /opt/acc/cfg/zcomdevice is not on the system or the
file has incorrect permissions.
Action: If the file exists, make sure it has read permissions set
for root, and that watch is being started by a superuser.
If the file does not exist, it must be either reinstalled,
or recreated. It can be recreated by running zdgen,
giving it the file /opt/acc/cfg/zcomdevice.txt as the
input file and /opt/acc/cfg/zcomdevice as the output
file.
watch 4 - Cannot find MONITOR device in /opt/acc/cfg/zcomdevice
Explanation: There is no MONITOR entry in the
/opt/acc/cfg/zcomdevice file.
Action: Reinstall the /opt/acc/cfg/zcomdevice and
/opt/acc/cfg/zcomdevice.txt files. If a custom .txt file is
being used to create /opt/acc/cfg/zcomdevice, make
sure it has an entry for MONITOR like the
zcomdevice.txt file that is provided with the ACC base
system product.
watch 5 - More than 1 MONITOR port (mux <num>, zlu=<num>)
Explanation: More than one MONITOR entry was defined for a
given Mux port in the .answ file corresponding to the
.tmem file used to bring up the ZCOM Mux subsystem.
Action: Fix the .answ file, rerun ttgen to create a new .tmem
file, stop the ZCOM Mux subsystem, and restart it
using the new .tmem file.