ACC Error Guide
ZX25D System Messages
CLASS: Warning 500-599
Chapter 12 261
zx25d 505 There are more PVCs configured (<#>) than subscribed to
(<#>) for the X.25 Link ZLU <#>.
Explanation: During the initialization of an X.25 link, the X.25
protocol driver detected that there were more PVC ZLU
terminal entries defined than were specified in the
X.25 subscription parameters. That is, the value of the
last_pvc parameter is less than the total number of
PVC ZLUs defined. The PVC ZLUs definitions that
exceed the last_pvc parameter value will not be
available for use.
Action: No action is necessary. This is an informational
message. However, it is recommended that you correct
the TTGEN configuration file.
zx25d 506 There are more two-way SVCs configured (<#>) than
subscribed to (<#>) for the X.25 Link ZLU <#>.
Explanation: During the initialization of an X.25 link, the X.25
protocol driver detected that there were more two-way
(x25.svc.io) SVC ZLU terminal entries defined than
were specified in the X.25 subscription parameters.
That is, the value of the (last_svc - first_svc) is less than
the total number of two-way SVC ZLUs defined. Some
of the SVC ZLUs may not be usable during run-time
operation.
Action: No action is necessary. This is an informational
message. However, it is recommended that you correct
the TTGEN configuration file.