ACC Error Guide
ZX25D System Messages
CLASS: Protocol 600-699
Chapter 12 279
zx25d 625 Link ZLU <#> reset; exceeded N2 retransmit limit.
Mux= <#>, Port= <#>, Subchannel= <#>.
Explanation: The X.25 link has experienced transmission errors and
the HDLC/LAP-B link has gone down because the N2
retransmission counter has been exceeded. The X.25
subsystem is in the process of re-establishing the X.25
link at level 2.
Action: No action is necessary. This is an informational
message.
zx25d 626 Link ZLU <#> reset due to transmitted FRMR
Mux= <#>, Port= <#>, Subchannel= <#>.
Explanation: The X.25 link has gone down due to the transmission of
a Frame Reject (FRMR). The reasons for generating a
FRMR are listed in message 606. The X.25 subsystem
is in the process of re-establishing the X.25 link at level
2.
Action: No action is necessary. This is an informational
message.
zx25d 627 Link ZLU <#> reset due to received FRMR.
Mux= <#>, Port= <#>, Subchannel= <#>.
Explanation: The X.25 link has gone down due to the receipt of a
Frame Reject (FRMR). The reasons for generating a
FRMR are listed in message 606. The X.25 subsystem
is in the process of re-establishing the X.25 link at level
2.
Action: No action is necessary. This is an informational
message.