ACC Error Guide
SNA/ACC Error Log Messages
SNACC Error Messages
Chapter 13 297
snacc 00195: ERROR (0xC3): ACC port is already in use.
Explanation: Configuration problem. The application number and
the Terminal type is defined incorrectly in the ACC
ttgen configuration file.
Action: Refer to SNA/ACC installation chapter for more
information on how to create ACC ttgen configuration
files to support the SNAplus2 subsystem.
snacc 00196: ERROR (0xC4): ACC port configuration failed. Function
called: <func name>; Return code: <#>
Explanation: The physical terminal is not configured in the ACC
ttgen configuration file.
Action: Refer to the SNA/ACC installation procedure for
information on creating a ttgen configuration file to
support SNAplus2.
snacc 00198: ERROR (0xC6): ACC terminal control request failed.
Function called: <func name>; Return code: <#>
Explanation: The SNA/ACC software called the ZCOM zsend()
function to configure a ZCOM port when establishing a
port for SNA usage. The zsend() function returned a
ZCOM error.
Action: Check the ZCOM log file for more information
regarding the state of the port, the card, or the ZCOM
subsystem to make sure everything has started up
properly. See Chapter 2, “ZCOM Error Codes,” for more
information on the ZCOM error condition.
snacc 00200: ERROR (0xC8): ACC terminal write request failed.
Explanation: The SNA/ACC software called the ZCOM zsend()
function to various control write strings, and zsend()
has returned an error.
Action: Check the ZCOM logfile for more information
regarding the state of the port, the card, or the ZCOM
subsystem to make sure everything has started up
properly. Refer Chapter 2, “ZCOM Error Codes,” for
information on the returned error condition.