ACC Error Guide
ZCOM Error Codes
Meanings of the Error Codes
Chapter 238
ZENDOWN (-61): Remote node is DOWN
Explanation: This error is returned whenever a request is issued for
a remote node that is not currently accessible by the
local ZCOM subsystem. That is, the local node has been
unable to establish communications with the specified
remote node. There are many reasons why this
condition can occur. The ZCOM subsystem may not be
running on the remote system, the local or remote
znode daemon may have been shutdown, the network
link(s) between the two systems may be down, or the
remote system may have failed.
Action: Check for abnormal conditions in the network, ZCOM
subsystems, or hardware and correct as necessary.
ZELSIZE (-62): Inconsistent storage size
Explanation: Logical data storage is assigned to unique labels. When
a call is made to allocate logical data storage for an
existing label, but the requested size is different from
that of the existing label, the system rejects the call
with this error.
Action: Determine the allocation size for that label (using
zscan) and correct the application source code.
ZEBADSIZE (-63): Can’t get storage of this size
Explanation: The zltstore routine returns this error when the system
cannot allocate logical data storage for the requested
size or the specified size is not a multiple of 8 which is a
storage size requirement.
Action: Increase the logical data area size specified by the
Logical-Size keyword in the TTGEN configuration file.