ACC Error Guide

ZCOM Error Codes
Meanings of the Error Codes
Chapter 252
ZeCARD_NOT_READY (-124): Mux not fully started up
Explanation: This error is returned when the LDM issues a LLIO
“READY” request to the DAM without having
successfully issued the correct sequence of LLIO
requests.
Action: Contact your HP support personnel.
ZeNO_RESTART (-125): Missing “RESTART” request
Explanation: This error is returned when the LDM issues a LLIO
ACTIVATE” request to the DAM without having
successfully issued a “RESTART” LLIO request first.
Action: Contact your HP support personnel.
ZeNO_IFT_ADDR (-126): Missing “ENABLE” request
Explanation: This error is returned when the LDM issues a LLIO
“RESTART” request to the DAM without having first
informed the DAM of its Interface Table address using
the LLIO “ENABLE” request.
Action: Contact your HP support personnel.
ZeDAM_NOT_BOUND (-127): DAM not bound to any hardware
Explanation: This error is returned when a request is issued to an
instance of the DAM for which there is no physical
hardware bound to it.
Action: Verify that the ACC Mux cards are correctly installed
in the backplane of your system. If the problem persist,
contact your HP support personnel.