ACC Utilities Reference Guide

WATCH - Mux Shutdown Feature
Configuration Requirements
Chapter 10 201
Configuration Requirements
The following configuration requirements must be met to use the watch
feature:
•The .zlnk file used to create the .zabs file being used must include
monitor.zrel.
Note that monitor.zrel is included in all .zlnk files that are provided
by the ACC base product, and is therefore available via all .zabs files
that are provided.
The ttgen .answ file that corresponds to the .tmem file used to start
zmon must have a MONITOR terminal entry per interface card.
The following example is for mux 3:
Term 123 3:7 MONITOR 0000h:0000h 01,0,0,0,0 ”Test Monitor
terminal”
Note that only one such terminal should be configured per interface
card, and only interface cards making use of this feature should have
this entry.
The ZLU parameter (shown as 123 here) must be unique among all
Term entries in the file.
The mux entry (shown as 3 here) must have been defined previously
in a Mux interface statement.
The port parameter (shown as 7 here) is arbitrary, but it must be in
the range 0 to 7.
All of the remaining parameters, with the exception of the comment,
must be given as shown.
NOTE The port referenced in the MONITOR terminal entry is not used for
communication between WATCH and MONITOR, but it must be present
nevertheless.