ACC Utilities Reference Guide

ZMNTR - ZCOM Runtime Monitor
Commands
Chapter 390
TM - Set Auto Repeat Time Interval
Format: TM,nn
The command sets the timeout value tonn” seconds between 0 and 200.
If set to 0, the timeout is cleared and the command does not repeat.
Otherwise the last command entered will be repeated every “nn
seconds.
Enter TM and the repeat time (anything between 1 and 5 inclusive is
treated as 5 seconds). Then enter the command to be repeated.
Use TM,0 to cancel the auto-repeat timeout and return to normal
operation.
Example
TM,30
TT,1,100
This sequence of commands will cause the TT,1,100 command to be
repeated every 30 seconds.
TO - Top of Form on List Device
Format: TO
This command causes a form feed to be sent to the printer. It has no
effect if the list device is a terminal.
TR - Set Transfer File
Format: TR,filename
TR is used to automate any repeated series of commands that are used
through ZMNTR. “filename” is the name of a file which consists of a
sequence of ZMNTR command strings, with one command per line.
These command strings are then performed automatically when the TR
command is used.