FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1203.01 HP Part Number: 5900-2228 Published: March 2012 Edition: 1.
Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview..............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Changed features................................................................................................................
This document provides information about the B.11.31.1203.01 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1203.01) documents version changes and defect fixes. New and changed features in this release New features There are no new features in this release.
Table 3 HP-UX September 2011 (AR1109) Fixes Defect ID QXCR1001131764 Description This fixes a memory leak in the fcd driver that occurs after concurrent execution of certain fcmsutil disable and ns_query_ports commands. QXCR1001068587 fcmsutil output has been modified to display target symbolic port and node names as "None" when respective symbolic name values are not returned by the targets.
Table 6 HP-UX September 2010 (AR1009) Fixes (continued) Defect ID Description QXCR1001012664 This fixes the fcmsutil's flash failure issue, due to the fcd driver misinterpreting a TAG field in the Vital Product Data. QXCR1001038471 SNIA does not provide speed for AH401A, so System Management Homepage (SMH) doesn't display speed for AH401A.
Table 11 HP-UX September 2009 Fixes Defect ID Description QXCR1000914828 This fixes an issue where the fcd startup script removed the volume group directory in /dev/fcd, followed by a number and vg name, such as /dev/fcd1dbvg03. QXCR1000844402 This fixes the issue where fcd converted an Illegal Request into SCTL_INCOMPLETE. The fix resolves the DS2405 open () performance issue, as well as the DS2405 firmware update failure issue.
It is strongly recommended that customers not use loop topology configurations for mezzanine adapters in conjunction with FC Pass Thru I/O interconnect modules. Customers are advised to use Point-to-Point Fabric topology configuration with mezzanine adapters. For additional information, please refer to HP Customer Advisory Document c02985353.
• Some PCIe I/O backplanes do not support PCIe2 (5.0 GT/s) cards on slots 3 and 4 PCIe I/O backplanes with product number AD295A #200 on rx3600, AD296A #200 on rx6600, and upgrade product number AD298A for both rx3600 and rx6600 Integrity servers, do not support PCIe2 (5.0 GT/s) cards on slots 3 and 4. PCIe2 cards will not be seen when seated in these slots. PCIe I/O backplanes with the product numbers AD295A #300, AD296A #300, and AD230A, do support PCIe2 cards on slots 3 and 4.
• crashconf displays incorrect size for dump devices FibrChanl-01 now supports dump devices that are greater than 2TB in size. However, crashconf displays an incorrect size for dump devices that are greater than 4TB. Corrective action: Install patch PHCO_36550 to fix this problem. This patch is delivered in the HWEnable11i patch bundle on the HP-UX 11i v3 (B.11.31) OEUR media for December 2007. You may also check availability of the patch at the HP IT Resource Center site: http:// itrc.hpc.
• Configuring an alternate path on the same 2–Port HBA as the primary path On midrange and high end Integrity servers, if the primary and alternate boot devices are on the same Fibre Channel HBA port, an attempt to manually boot from the alternate device will fail. For example, if your primary and alternate paths are set as follows: Primary bootpath: 0/0/10/1/0/4/0.8.0.255.0.7.0 Alternate bootpath: 0/0/10/1/0/4/0.8.0.255.0.0.
NOTE: The FC-COMMON.FC-SNIA fileset is part of the CommonIO bundle. If FC-COMMON.FC-SNIA (B.11.31.0709 or later) is not present on a system, swinstall of theFC-FCD product will display errors. If you ignore the errors and proceed with the swinstall, the FC-FCD.FC-FCD-RUN fileset will not be installed. Driver bundles can be downloaded from the HP Software Depot at: http://www.software.hp.com Patches are available from either: http://www.software.hp.com or http://itresourcecenter.hp.
Table 17 Table of Driver Versions Release Name Driver Version Release Date Initial 11.31 Support B.11.31 February 2007 Application Release 0709 B.11.31.0709 September 2007 Application Release 0803 B.11.31.0803 March 2008 Application Release 0809 B.11.31.0809 September 2008 Application Release 0903 B.11.31.0903 March 2009 Application Release 0909 B.11.31.0909 September 2009 Application Release 1003 B.11.31.1003 March 2010 Web Release 1003 B.11.31.1003.
Related information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 is available at http://www.hp.com/go/hpux-iocards-docs, under the HP Fibre Channel Host Bus Adapters section. Available documents include: • Support Guide: includes an adapter overview, installation details, adapter configuration, troubleshooting and maintenance information, additional features, and regulatory information.