FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Version Number B.11.23.0909 HP Part Number: J6374-90080 Published: September 2009 Edition: 4.
Legal Notices © Copyright 2009 Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor’s standard commercial license. The information contained herein is subject to change without notice.
Table of Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview...........................5 New and Changed Features in This Release..........................................................................................5 Defect Fixes.............................................................................................................................................5 Driver Versions.....................................................................................
List of Tables 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 4 HP-UX 11i v2 September 2009 Fixes...............................................................................................5 HP-UX 11i v2 March 2009 Fixes......................................................................................................5 HP-UX 11i v2 November 2008 Fixes...............................................................................................5 HP-UX 11i v2 September 2008 Fixes.............................
This document provides information about the B.11.23.0909 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Overview This release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 (version B.11.23.0909) provides fixes for defects listed in Table 1. New and Changed Features in This Release There are no new features with this release.
Table 6 HP-UX 11i v2 December 2007 Fixes Defect ID Description CR: JAGag48556 fcd driver fails HBA initialization, when WEL bit is set in the NVRAM status register. CR: JAGag41528 Fixed an out-of-bounds array reference in the fcd SNIA library that caused core dumps. Fixed an infinite loop condition in the fcd SNIA library. Table 7 HP-UX 11i v2 September 2007 Fixes Defect ID Description SR: 8606487612 Fixed fcmsutil to accept the multiboot image with embedded firmware for flashing.
Table 11 HP-UX 11i v2 June 2006 Fixes Defect ID SR: 8606440419 Description Resolved a problem that could cause a system panic during system boot. Table 12 HP-UX 11i v2 December 2005 Fixes Defect ID Description SR: 8606413902 After installation of PHKL_30257 MO library drives in a 10-drive optical jukebox in SCC mode are not visible any more. By changing to indexed mapping 8 devices are visible, not all 10 drives.
Table 13 HP-UX 11i v2 March 2005 Fixes (continued) Defect ID Description SR: 8606369480 The fcd driver is not seeing devices through the Cisco MDS 9000 family of switches SR: 8606394349 SAN configuration changes might lead to boot failure from devices seen by the fcd driver.
Known Problems and Limitations This section provides a list of known problems and limitations as known to HP at time of publication. If workarounds are available, they are included. • EFI SEARCH Causes Boot to Fail on rx7640, rx8640, and sx2000 Superdome Server Systems Running the SEARCH command at the EFI shell on rx7640, rx8640, and HP Integrity Superdome/SX2000 server systems can cause the system to fail to boot through a Fibre Channel HBA. rx7640 systems have a built-in SEARCH of slot 7.
• Increased Boot Time with Unconnected fcd HBA Ports System boot time will be increased if there are unconnected fcd HBA ports (i.e., HBA ports controlled by the fcd driver). This happens because an ioscan is performed as a part of the boot process for HP-UX . When an ioscan is performed for the first time for an fcd HBA port, the fcd driver waits for 21 seconds before declaring the port offline. This is only an issue during boot, because at boot time the HBA ports are scanned sequentially.
Requirements for Boot Support: AD193A/AD194A, 403619–B21, AB378A, AB378B, AB379A, AB379B. A6826A. A9782A, A9784A, AB465A To boot through the fibre channel ports on these adapters, HP recommends that you update the EFI driver and onboard firmware to the latest version. The following table lists the recommended EFI and firmware versions at the release of FibrChanl-01 (fcd) driver, version B.11.23.
Related Information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 is available at http://www.docs.hp.com, under the I/O Cards and Networking Software section in the Fibre Channel category. Available documents include: • • • • Support Guide: includes an adapter overview, installation details, adapter configuration, troubleshooting and maintenance information, additional features, and regulatory information.