FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Version Number B.11.23.1003 HP Part Number: 5900-0485 Published: March 2010 Edition: 1.
Table of Contents FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2 overview...........................5 New and changed features in this release..............................................................................................5 New features.....................................................................................................................................5 Known problems fixed in this version...................................................................
List of Tables 1 2 3 4 5 6 7 4 HP-UX March 2010 (AR1003) Fixes................................................................................................5 HP-UX September 2009 Fixes..........................................................................................................5 HP-UX March 2009 Fixes................................................................................................................5 HP-UX December 2008 Fixes.......................................................
This document provides information about the B.11.23.1003 release of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2. FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2 overview This release of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v2 (version B.11.23.1003) documents version changes. New and changed features in this release New features The following feature is new with the B.11.23.
Table 6 HP-UX December 2007 Fixes Defect ID SR 8606488089 Description Fixed a critical issue which occurs when using the fclp driver to perform I/O to sequential blocks of one LUN from mulitple virtual memory address spaces, such as I/O to a swap device. The issue caused incorrect data to be swapped in and out, which resulted in application core dumps or kernel panics. The issue is present in FibrChanl-02 software (fclp driver) versions B.11.23.0706 and B.11.23.0709; version B.11.23.
This issue will be addressed in a future system firmware update. It can be caused by entering the EFI shell without having configured boot devices in the EFI driver's configuration screens. There are three workarounds for this issue: — — — • Return to the Boot Manager, enter and exit the EFI shell a second time, and retry the boot; or, Reset the system and retry the boot; or, Configure the EFI driver to always map the boot devices using the drvcfg -s at the EFI shell prompt.
6. 7. 8. 9. • Select (highlight) the Configure HBA Parameters option and press Enter. Select (highlight) the Force Link Speed option and press Enter. Select (highlight) the 2Gb/s link speed option from the list presented, and press Enter. After completing your selection, use the ESC key to exit the EFI configuration menus.
• • PHKL_31500 patch or later (needed for HP-UX 11i v2) PHKL_34851 (needed for HP-UX 11i v2) Driver bundles can be downloaded from the HP Software Depot at: http://www.software.hp.com Patches are available from either: http://www.software.hp.com or http://itresourcecenter.hp.com OnlineDiag is available at http://www.software.hp.com in the Enhancement releases and patch bundles section, or on the HP-UX 11i v2 OE media (September 2004 and later). Installation instructions are available at: http://docs.hp.
Software availability in native languages This product is available only in the English language.