FibrChanl-02 (fclp) B.11.23.1003 Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes

6. Select (highlight) the Configure HBA Parameters option and press Enter.
7. Select (highlight) the Force Link Speed option and press Enter.
8. Select (highlight) the 2Gb/s link speed option from the list presented, and press Enter.
9. After completing your selection, use the ESC key to exit the EFI configuration menus.
Configuring an alternate path on the same 2-port HBA as the primary path
On midrange and high end Integrity servers, if the primary and alternate boot devices are
on the same Fibre Channel HBA port, an attempt to manually boot from the alternate device
will fail.
For example, if your primary and alternate paths are set as follows:
Primary bootpath: 0/0/10/1/0/4/0.8.0.255.0.7.0
Alternate bootpath: 0/0/10/1/0/4/0.8.0.255.0.0.0
This will set the primary and alternate bootpaths, but you will only be able to boot from the
primary path.
Corrective action:The issue can be resolved by following one of the following scenarios:
— From the EFI shell: Manually issue the EFI shell command reconnect r, before
attempting to boot from the alternate path.
— Online: Use the HP-UX setboot command to swap the primary and alternate boot
devices.
Hardware configuration: Reconfigure by moving the alternate boot device to a different
HBA
Using ioscan with krm not running
When ioscan is run with the fn or Fn option, and the kernel resource monitor (krm) is
not running, there could be stale krm device files in the system, which would correspond
to different devices, including fclp, in ioscan output. This issue has no impact on the
functionality of the Fibre Channel port; however, ioscan output may be confusing. This
issue can impact any card accessible with ioscan, and is not specific to the cards supported
by the fclp driver.
Corrective action:The ioscan output can be returned to normal by either deleting the stale
krm device files, or by starting krm, which will recreate the device files.
Compatibility and installation requirements
This section describes the compatibility information and installation requirements for this release.
For specific installation instructions, refer to the installation guide specific to your to your
FibreChannel card.
NOTE: FibrChanl-02 on HP-UX 11i v2 is supported with VxVM 4.1 or later, including boot and
Ignite/UX.
Operating system and version compatibility
The following software (or later versions) must be installed before installing the FibrChanl-02
(fclp) driver, version B.11.23.1003 into a system:
FibrChanl-00 (td) version B.11.23.03 or later (for HP-UX 11i v2 Update 3)
Fibre Channel Mass Storage (FCMassStorage) version B.11.23.03 or later
Product number B6191AAE, OnlineDiag bundle version B.11.23.0903, released in March
2009 (HWE0903)
PHKL_36363 patch or later (for HP-UX 11i v2)
PHKL_36143 patch (needed to enable thefcmsutil command to work properly with cards
that use the fclp driver)
8