HP A7143A RAID160 SA Controller Support Guide

Troubleshooting
The sautil Command
Chapter 6 119
Firmware Revision (inactive)........ 2.92
# of Logical Drives................. 1
# of Physical Disks Configured...... 4
# of Physical Disks Detected........ 4
Logical Drive Rebuild Priority...... 118 (high)
Array Capacity Expansion Priority... 0 (low)
Auto-fail Missing Disks at Boot..... enabled
---- ARRAY ACCELERATOR (CACHE) INFORMATION -----------------------------------
Array Accelerator Board Present?.... yes
Cache Configuration Status.......... cache enabled
Cache Ratio......................... 50% Read / 50% Write
Total Cache Size (MB)............... 256
Read Cache........................ 112
Write Cache....................... 112
Transfer Buffer................... 032
Battery Pack Count.................. 2
Battery Status (pack #1)............ ok
Battery Status (pack #2)............ ok
---- LOGICAL DRIVE SUMMARY ---------------------------------------------------
# RAID Size Status
0 1+0 17365 MB OK
---- SCSI DEVICE SUMMARY -----------------------------------------------------
Ch ID Type Capacity Status
1 0 DISK 18.2 GB OK
1 1 DISK 18.2 GB OK
1 2 DISK 18.2 GB SPARE
1 3 DISK 18.2 GB SPARE
1 7 PROCESSOR N/A N/A
---- LOGICAL DRIVE 0 ---------------------------------------------------------
Logical Device File................. c6t0d0
Fault Tolerance Mode................ RAID 1+0 (Disk Mirroring)
Logical Drive Size.................. 17365 MB